• evo视讯(中国)

    Gibson Assembly® Master Mix – Assembly (E2611)

    New England Biolabs

    Published: 2022-02-16 DOI: 10.17504/protocols.io.bdd8i29w
    AI 解读
    浏览 1580

    Abstract

    This protocol explains methods for the Gibson Assembly using the Gibson Assembly® Master Mix (E2611).

    Before start

    Steps

    1.

    Set up the following reaction On ice:

    ABCD
    Recommended Amount of Fragments Used for Assembly
    2-3 Fragment Assembly4-6 Fragment AssemblyPositive Control**
    Total Amount of Fragments0.02-0.5 pmols*X ul0.2-1 pmols*X ul10 ul
    Gibson Assembly Master Mix (2X)10 μl10 μl10 μl
    Deionized H2O10-X μl10-X μl0
    Total Volume20 μl***20 μl***20 μl

    *Optimized cloning efficiency is 50–100 ng of vectors with 2–3 fold of excess inserts. Use 5 times more of inserts if size is less than 200 bps. Total volume of unpurified PCR fragments in Gibson Assembly reaction should not exceed 20%.**Control reagents are provided for 5 experiments.***If greater numbers of fragments are assembled, additional Gibson Assembly Master Mix may be required.

    2.

    Incubate samples in a thermocycler at 50°C for 0h 15m 0s when 2 or 3 fragments are being assembled or 1h 0m 0s when 4-6 fragments are being assembled.

    Note
    Extended incubation up to 1h 0m 0s may help to improve assembly efficiency in some cases (for further details see Extended incubation up to may help to improve assembly efficiency in some cases (for further details see FAQ section).).

    3.

    Store samples on ice or at -20°C for subsequent transformation.